LED Handheld Explosion-Proof Searchlight

Model: HRZC-SD7102

Explosion-proof Marking:Ex db ib IIC T6 Gb


Leave a Message >

▲1. The structure of this product complies with the standards of **GB/T 3836.1-2021 Explosive atmospheres — Part 1: General requirements for equipment**, **GB/T 3836.2-2021 Explosive atmospheres — Part 2: Equipment protected by flameproof enclosure "d"**, and **GB/T 3836.4-2021 Explosive atmospheres — Part 4: Equipment protected by intrinsic safety "i"**. ▲2. Explosion-proof Marking: Ex db ib IIC T6 Gb. It is supplied with explosion-proof test report and explosion-proof certificate. 3. Equipped with 3 high-power LED chips; Rated Power: 3×3W. 4. Rated Voltage: ≤4.2V; Rated Capacity: ≥7800mAh. 5. Continuous stable working time: ≥5 hours (High beam) / ≥15 hours (Low beam). ▲6. Housing Ingress Protection Rating: ≥IP66. 7. Operation Mode: High beam – Low beam – Strobe – Off. 8. Housing Material: High-grade 6061-T6 aviation aluminum alloy (sandblasted and anodized treatment). 9. Dimensions: ≤154×69 mm. 10. Lens Material: Tempered optical glass. 11. Power Indication: Low battery reminder on the handle. Green light indicates full power; red light lights up when remaining power is less than 20%. 12. Powered by 3 pieces of 18650 high-energy lithium-ion polymer batteries. Built-in battery protection circuit provides overcharge, overdischarge and short-circuit protection. ▲13. After four drop tests from a height of 1 meter, no damage caused by the test shall impair the explosion-proof performance of the electrical equipment. ▲14. The flameproof performance meets the test requirements of IIC electrical equipment: No explosive transmission occurs after 5 internal ignition tests with 7.5% C₂H₂ gas; no explosive transmission occurs after 5 internal ignition tests with 27.5% H₂ gas. ▲15. A test voltage of 1500V is applied between non-intrinsic safety terminals and intrinsic safety terminals for no less than 1 minute without dielectric breakdown. A test voltage of 500V is applied between non-intrinsic safety terminals and enclosure, as well as between intrinsic safety terminals and enclosure for no less than 1 minute, with no dielectric breakdown. ▲16. Sealing rings and adhesive seals: No obvious deterioration after 672 hours storage at 95 °C and 90% relative humidity; no obvious deterioration after 24 hours storage at -25 °C. 17. Test reports marked with CMA or CNAS issued by nationally recognized third-party testing institutions shall be provided. All items marked with ▲ shall be covered in the test reports.